outer insulation造句
例句與造句
- Using for end of coil and outer insulation of electric component
用于電子器件的外部絕緣和線圈的末端。 - Cut out insulation around pressure taps so that when diagnostic checks are required , plugs are visible when outside shell is removed as shown in fig . 3
當(dāng)需要進(jìn)行診斷檢測時(shí),切開環(huán)繞測壓孔周圍的保溫材料,使得外殼拆卸后能夠看到塞子,如圖3所示。 - Based on the detailed investigation about the present conditions of polution in yichang and three gorges dc converter stations and its prediction , and concerning the esdd measurement of dc , ac equipment near the three gorges dc converter station , the operating experience and the atmospheric characters of the yichang city , the porper data of esdd of three gorges dc converter station is presented . and further more , presents the related structural parameters of outer insulation of out door dc , ac equiptment
針對(duì)宜昌市大氣污染和三峽換流站站址附近污穢狀況,結(jié)合三峽換流站附近交、直流設(shè)備鹽密測量和運(yùn)行經(jīng)驗(yàn)以及宜昌氣候特征,提出了三峽換流站適用的等值附鹽密度值,并在此基礎(chǔ)上提出了交、直流戶外設(shè)備外絕緣的有關(guān)結(jié)構(gòu)參數(shù)。 - Only when it takes humidity ratio h / ? as independent variable instead of absolute humidity h in researching and calculating the influence degree of the humidity on the discharge voltage , the emendation coefficients of relative air density and humidity can be independence , and can reflect the influence degree of atmospheric parameters on outer insulation discharge voltage actually
當(dāng)以比濕h代替絕對(duì)濕度h為自變量研究和計(jì)算濕度對(duì)放電電壓的影響程度時(shí),相對(duì)空氣密度校正系數(shù)和濕度校正系數(shù)才能相互獨(dú)立,才能真實(shí)地反映大氣參數(shù)對(duì)電氣設(shè)備外絕緣放電電壓的影響程度。 - Based on instance of mania project , the article raises an insulation coordination method for high elevation zone and the criterions fulfilling the insulation coordination conditions . it also has calculated the demanding values of withstanding voltage of all voltage levels equipment , and the results of outer insulation coordination . at the mean time , it proves the success of applying " humidity ratio " integrated emendation method in the mania project
文中又根據(jù)滿拉工程實(shí)例,提出適合高海拔地區(qū)使用條件的絕緣配合方法及滿足絕緣配合條件的判據(jù);采用“比濕”綜合校正法計(jì)算了滿拉工程各級(jí)電壓設(shè)備耐受電壓要求值及外絕緣配合成果,同時(shí)也證明“比濕”綜合校正法在滿拉工程應(yīng)用的成功。 - It's difficult to find outer insulation in a sentence. 用outer insulation造句挺難的
- Researching and analyzing on the test results of the influence of atmospheric parameters on outer insulation discharge voltage and its various emendation methods , it can be concluded that : with the change of relative air density , its humidity ratio h / ? will also change even though the absolute vapor mass ( absolute humidity h ) of the air is constant . consequently , the influence degree of the humidity on the discharge voltage should change , too
本文通過對(duì)以往的大氣參數(shù)對(duì)外絕緣放電電壓影響的試驗(yàn)成果及各種校正方法的研究分析認(rèn)為:隨著相對(duì)空氣密度的變化,即使空氣中所含水氣的絕對(duì)質(zhì)量(絕對(duì)濕度h )保持恒定,其比濕h也會(huì)變化,必然地,濕度對(duì)放電電壓的影響程度也會(huì)變化。 - It compares and analyses the equipment test voltage emendated to standard atmosphere conditions with the equipment nominal withstanding voltage . and then it concluded that : the emendation value educed by " humidity ratio " integrated emendation method is basically equal or close to the equipment nominal withstanding voltage ; but the values by two traditional emendation methods are mostly higher . it also proves that , " humidity ratio " integrated emendation method is more perfect than any other methods , and it can reflect the influence degree of atmospheric parameters on electrical equipment outer insulation discharge voltage actually
文中選擇“比濕”綜合校正法和兩種傳統(tǒng)校正法,分別對(duì)西高所為羊八井、拉薩、羊湖110kv變電所設(shè)備所做的人工氣候室模擬試驗(yàn)數(shù)據(jù)及云南中試所做的zs - 110工頻放電電壓試驗(yàn)數(shù)據(jù)進(jìn)行校正計(jì)算,將試驗(yàn)電壓的校正值與試驗(yàn)設(shè)備的標(biāo)稱耐受電壓水平進(jìn)行比較分析;認(rèn)為: “比濕”綜合校正法的校正值與設(shè)備耐受電壓水平基本相等或接近,而兩傳統(tǒng)校正法的校正值大多高于設(shè)備耐受電壓水平;進(jìn)一步證明, “比濕”綜合校正法是目前諸多校正法中較為完善的,能真實(shí)地反映大氣參數(shù)對(duì)電氣設(shè)備外絕緣放電電壓的影響程度的校正法,在高海拔電力工程設(shè)計(jì)中應(yīng)推廣應(yīng)用。 - According to the practice on gezhouba to shanghai hvdc transmission project and in consideration of condition on three gorges hvdc project , some suggestions on protection of overvoltage and insulation coordination for outer insulation , against pollution - wet , dc neutral bus over - voltage and dc & ac filter are technically presented . it may be a reference in design of three gorges converter station
根據(jù)葛南直流工程的經(jīng)驗(yàn)并結(jié)合三峽工程的情況,在換流站的外絕緣、直流耐污濕技術(shù)、直流中性母線過電壓防護(hù)、交直流濾波器的過電壓防護(hù)等方面提出了過電壓和絕緣配合的技術(shù)要求,供設(shè)計(jì)參考。